BRAND | Isotech |
Product | DAkkS-Kalibrierung im Bereich -38 °C bis 660 °C |
Description | DAkkS calibration |
Internal code | IMP4712135 |
Technical specification | DAkkS calibration of a standard working thermometer Available at the fixed points of the ITS-90. Measurement uncertainties: Mercury -38.8344 °C 3.5 mK Water triple point 0.01 °C 2.5 mK Gallium 29.7646 °C 2.5 mK Tin 231.928 °C 7.0 mK Zinc 419.527 °C 12 mK Aluminium 660.323 °C 20 mK The measurement uncertainties that can be achieved depend from the examinee. Some typical measurement uncertainties can be found at: https://www.klasmeier.com/mu/ The fixed points are defined according to the temperature ranges the ITS-90 selected. Before calibration, the Working standard thermometer has aged sufficiently. Hydrostatic pressure effects that occur in fixed-point cells occur, are corrected. Self-heating and The hysteresis of the normal working thermometer is Start of calibration examined and when specified which takes into account calibration results. Als Calibration results will be the resistance and W values of the normal working thermometer are given, as well as two characteristic curves (coefficients) in accordance with ITS-90 calculated (with measurement current 0 mA and 1 mA if not specify differently). The minimum immersion depth of |
Please Contact Us to Order to offer competitive prices and delivery time for Isotech - DAkkS-Kalibrierung im Bereich -38 °C bis 660 °C DAkkS calibration number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Polska Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Milliohm meter
milliK Präzisionsthermometer
30 ° C to 300 ° C Uncertainty: absolute ± 0.0005 ° C (with FP-cells) vertical ± 0.003 ° C ± 0.001 ° C in the vicinity of the ambient temperature to ± 0.001 ° C when compared calibration Liquid quantity: 7 liters Workspace: 100mm 400mm deep incl. RS 232 interface 240V - 50 Hz Further description gem. data sheet
High Temperature-Blockcalibrator
Temperature Range to 1200°C With standard Insert (Standard 4 x Ø 8 mm)853-06-01 Calibration volume: Ø 33,5 x 130mm Temperature Range: 150°C bis +1200°C Stabilität: ± 0,1°C Resolution: ± 1 Digit 220VAC - 50Hz, 1500W Referencethermocouple Type R (935-14-91) Software PC connecting cable, „RS232“
ISOTECH 909H/Pt100 Temperature Range: -80°C to 550°C Wga > 1,11807 ITS-90 conditions Diameter: 6 mm Length: 480 mm Metal cover Cable length 2 m, Connecting terminal gold-plated. BNC connector
STANDARD KALIBRIEREINSATZ HYPERION & DRAGO
(Standard calibration insert for BlockkalibratorenHyperion and Drago. with the following holes: - 8 x 8 mm dia - 2 x 4.5 mm diameter)
(Suitable for Isotech dry-wells with wheels and Trapeze handle.)
(Liquid container made of stainless steel)
Hyperion Advancedzur Kalibrierung von Thermofühlern vor Ortim Temperaturbereich von -25 °C bis + 140
ADVANCED Hyperion
Calibration, System (-80°C to 660°C)
Normalthermoelement Modell
Normalthermoelement Modell
Normalthermoelement Modell
Isolationsprüfgerät
Thermocouple Reference Unit
thermocouple cold junction
thermocouple cold junction
thermocouple cold junction
thermocouple cold junction
Precision thermometer
Normal - Platinwiderstandsthermometer